Product Overview

Highlights

During postnatal care and resuscitation of newborn and pre-term babies the first minutes after birth are decisive. There must be available all the equipment to clear the airway, to apply oxygen or even to ventilate the baby if necessary. Above all, however, the baby requires warming in order to adapt to the new environment. The infant care system VARIOTHERM REA-KCE has been specifically designed for these conditions, allowing full access for the procedures to be carried out in this situation.

The infant care system is equipped with an under-pad heating device and an infra-red radiant warmer. Upgraded with specific accessories it can be used for the warming therapy or intensive care of pre-term babies.

Height-adjustment for ergonomic working

The solid trolley has 4 large anti-static castors which can be locked in any position. So it is very easy to move the infant care system around. Additional bumpers avoid damage to the device and the furniture. The desired working height can simply be adjusted by easily accessible foot pedals. These can be arranged at choice at the front or either side of the device.

Head-up/feet down or feet up/head down position

The patient area can be inclined into head-up/feet down or feet up/head down position very quickly. Raised sides prevent the infant from trundling out of the bassinet.

Enough storage space

For storing accessories a shelf or two large drawers can be integrated in the trolley.

Always everything available

At the rearside an oxygen or/and compressed air bottle can be fitted.

Sophisticated perspex wall assembly

All perspex walls can be folded down and up again by one hand. Tubings and leads are fed through the grommets in the rear wall. Two perspex safety side walls which are part of the basic configuration of the device secure the patient when the side walls are folded down. In case of side walls folded up these safety walls improve the thermal conditions, similar to the well-known double- wall effect. During treatment they can be retracted into the bassinet.

Under-pad heating device with anti-decubitus gel pad

The comfortable warmth of the conductive under-pad heating device with anti-decubitus gel pad warms up even hypothermic infants quickly and efficiently. The standard temperature selection range of 35° to 37° can be increased via safety lock to 30° to 38.5°. Selected and actual temperature are displayed as well as the residual heat when the device is switched-off. Alarms are provided for high and low temperature, system faults and power failure. A separate safety circuit switches off the heating in the case of fault.

Radiant warmer

The radiant warmer CERAMOTHERM provides additional efficient and safe warming. Long-life ceramic heating elements supply infrared radiation which is evenly distributed over the patient area.. The radiation spectrum is in the far, invisible and well tolerated infra-red B range.Two fluorescent lamps illuminate the patient area evenly. The natural light spectrum guarantees an excellent visual assessment of the patient. In order to avoid that patient or user are dazzled by the light we very consciously refrained from using focussed halogen or LED light.

Swivelling radiant warmer

For taking X-ray, or in order to reduce the heat exposure to the staff, the radiant warmer can be swiveled away, whereas, however, the radiation is still focussed on the patient.

Always the right climate

The radiation intensity can be selected according to the individual treatment situation. Especially in combination with the under-pad heating often a low intensity selection is sufficient, thus reducing the transepidermal humidity losses in the patient.

Both the selected radiation intensity as well as the actually emitted intensity are displayed defined in mW/cm². When comparing to the patient's physical values taken in regular intervals, important conclusions can be drawn on his requirement of heat and his metabolism. The attained information contributes to a clear diagnosis and successful treatment. When the radiant warmer is switched-off the residual heat will be displayed until the heating elements have cooled-off.

Alarms

Visual and audible alarm is provided for deviation between selected and actual intensity as well as for system faults and power failure. In case of high intensity selection after 15 minutes of operation a visual and audible alarm is released and the intensity output is automatically reduced to a safe value. When the user confirms the high intensity selection by pushbutton, the radiant warmer will continue to operate with the high intensity for the next 15 minutes.

Wide choice of accessories

The accessory components from the THERMOCARE and VARIOTHERM program are compatible and can be fixed at the high-grade steel tube assembly or at an instrument rail.

Produktdetails

Order No. WY2043  Infant care system VARIOTHERM REA-KCE
Height-adjustable, with under-pad heating device and radiant warmer CERAMOTHERM 2200

General data

  • Base device

    Depth 1140 mm
    Width 585 mm
    Height 1830 to 2130 mm
    Weight 90 kg
    Height adjustment, range 300 mm
    Castors Ø 125 mm / kickstop 4 / 4
    Bumpers Ø 70 mm 4

    Patient area

    Depth 760 mm
    Width 480 mm
    Height 850 mm to 1150 mm
    Head-up/feet down position 0 to 20°
    Feet up/head down position 0 to 10°
    Perspex walls, fold-down 4 / 170 mm high
    Safety perspex side walls, retractable 2

    Under-pad heating device

    Gel pad, conductive Yes
    Pad, non-conductive No

    Radiant warmer

    Tube assembly with radiant warmer CERAMOTHERM 2200
    Radiant warmer swiveling Yes

Performance and operating data

  • General data

    Operating voltage / power supply ~230 V – 50 Hz
    Max. power input - base device 1550 W / 6,7 A
    Max. power input - incl. additional devices 2300 W / 10 A
    Take-off sockets for additional devices 1 x 200 W, 1 x 50 W, 2 x 250 W

    Under-pad heating device

    Self-test Yes
    Temperature selection – standard range 35°C to 37°C
    Temperature selection – Extended range 30°C to 38,5°C
    Temperature selection display Yes
    Actual temperature/residual heat display Yes
    Alarm for temperature deviation ± 1°C Yes
    Safety cut-off at 40°C Yes
    Power failure alarm Yes

    Radiant warmer

    Heating elements, ceramic 2 x 400
    Wave length spectrum 1500 to 6800 nm
    Illumination 2 x 18 W
    Self-test Yes
    Intensity selection 2 to 22 mW/cm²
    Intensity selection display Yes
    Actual intensity / residual heat display Yes
    Alarm for intensity deviation ± 2 mW/cm² Yes
    Alarm / automatic intensity reduction after 15 minutes > 10 mW/cm², Yes
    Alarm / automatic intensity reduction can be switched-off temporarily Yes
    Power failure alarm Yes

Colours

Trolley White RAL 9002
Bassinet White RAL 9010
Radiant warmer White RAL 9010

Classification and standards

Protection class 1
Device type B
MDD-class IIa
EN 60601-1:2006 Yes
EN 60601:1-2:2007 Yes
EN 80601-2-35:2010* Yes
EN 60601-2-21:2009** Yes
  * Particular requirements for the basic safety of heating devices using blankets, pads and mattresses and intended for heating in medical use
  ** Particular requirements for basic safety of infant radiant warmers

Maintenance

Inspection Yearly
Preventive maintenance Yearly

Zubehör

  • Order No. Description
    WY2060 Shelf for the trolley, with raised sides and instrument rail 25 x 10 mm, load max. 20 kg.
    or optionally:  
    WY2061 Drawer assembly for the trolley, 2 self-closing drawers with 100 % sliding tandem guidance , top side designed as shelf, with raised sides and instrument rail 25 x 10 mm,
    load max. 20 kg. Incl. 1 organizer and 1 tray which can be clipped on the side wall.
    WY2067 High-grade steel infusion pole Ø 25 mm, 600 mm long,
    fixed at the instrument and monitor shelf
    WY2068 High-grade steel infusion pole Ø 25 mm, height-adjustable,
    fixed at the instrument and monitor shelf
    WY2075 High-grade steel infusion pole Ø 25 mm, height-adjustable,
    fixed at the high-grade steel tube Ø 40 mm
    WY2062
    WY2065 High-grade steel instrument rail 25 x 10 mm, cranked,
    for fixing large devices and components at the high-grade steel tube Ø 40 mm
    WY2063 Instrument and monitor shelf 420 x 280 mm,
    fixed at the high-grade steel tube Ø 40 mm, load max. 20 kg
    WY1004 APGAR DIGITEMP Temperature monitor with integrated Apgar timer,
    fixed at the high-grade steel tube Ø 40 mm.
    Timer for performing the Apgar test and monitor for measuring the patient temperature.
    Normal clock mode.
    Timer mode with signal after 1 - 2 - 5 and 10 minutes.
    Skin temperature mode with high and low temperature alarm.
    Alarm can be reset for 15 minutes and switched-off temporarily if necessary.
    Incl. reusable skin sensor.

    Suction / oxygen supply

    Order No. Description
    WY1620 Suction unit for compressed air operation, for connection to central pipeline.
    Vacuum can be adjusted from 0 to 0.6 bar and switched-off, suction capacity 27 l/min.,
    incl. suction bottle 250 ml, suction lid with float assembly, suction tube, pressure hose and clamp for instrument rail 25 x 10 mm.
    WY1604 Precision oxygen flow meter for connection to central pipeline, pressure compensated,
    flow adjustable 0 to 15 l/min., incl. pressure hose and clamp for instrument rail 25 x 10 mm.
    WY1621 Precision oxygen flow meter, with bubble humidifier,
    for connection to central pipeline, pressure compensated, flow adjustable 0 to 15 l/min.,
    incl. pressure hose and clamp for instrument rail 25 x 10 mm.
    WY1472 Suction and insufflation assembly, compact unit, consisting of:
    - Precision oxygen/air blender with on-off switch,
    oxygen concentration adjustable 21 to 100 %,
    gas failure alarm,
    application via precision oxygen/air flow meter,
    flow adjustable 0 to 15 l/min.
    - Suction unit for compressed air operation,
    vacuum can be adjusted from 0 to 0.6 bar and switched-off,
    suction capacity 27 l/min., incl. suction bottle 250 ml,
    suction lid with float assembly, suction tube.
    Connection to oxygen and compressed air supply
    (central pipeline or cylinders), operating pressure 3 to 5 bar,
    oxygen and air NIST fittings.
    Incl. pressure hoses and clamp for instrument rail 25 x 10 mm.
    WY1473 Insufflation assembly, compact unit, consisting of:
    - Precision oxygen/air blender with on-off switch,
    oxygen concentration adjustable 21 to 100 %,
    gas failure alarm,
    application via precision oxygen/air flowmeter,
    flow adjustable 0 to 15 l/min.
    Connection to oxygen and compressed air supply
    (central pipeline or cylinders), operating pressure 3 to 5 bar,
    oxygen and Air NIST fittings.
    Incl. pressure hoses and clamp for instrument rail 25 x 10 mm.
    WY1421 Oxygen distributor with 3 take-off sockets, incl. pressure hose and clamp for instrument rail 25 x 10 mm
    WY1425 Compressed air distributor with 3 take-off sockets, incl. pressure hose and clamp for instrument rail 25 x 10 mm
    WY2066 Holder for oxygen cylinder 10 l.
    B0700 Holder for 2 gas cylinders up to 104 mm Ø.
    WY1612 Pressure regulator with connection R 3/4" and take-off socket 5 bar.
    WY1614 Air pressure regulator with connection R 5/8" and hose connection 5 bar

    Manual resuscitation

    Order No. Description
    WY1465 Baby-resuscitation bag with paedi-valve, incl. 1 each face mask size 0 and 1
    WY1466 PEEP-valve 0 - 10 mbar for resuscitation bag.

    Phototherapy

    Order No. Description
    WY1816 BILICOMPACT®
    Phototherapy device for treatment of the neonatal hyperbilirubinemia,
    10 energy saving lamps Blue BAM/PL9/52, wave length spectrum 460 nm,
    integrated hour counter, handles.
    WY2003 Height-adjustable mobile stand
    for phototherapy device BILICOMPACT,
    with 4 antistatic castors, 2 of them with kickstop,
    necessary underpin height > 95 mm,
    bottom side of the phototherapy device height-adjustable
    1315 to 1675 mm, rotation 360°, vertical adjustment ± 45°.

Do you have questions?

Tel.: +49 (0)2207 9698-0
E-Mail: info@weyermed.com


Brochure

Print this page